Lucent Technologies Network Card P N 80051 User Manual

DS2000 PC Card Instructions for Backup,  
Restore and Software Upgrade (U Slot Software)  
Use PC Card P/N 85880 to back up and restore your site data. Use PC Card P/N 80051-V**.** to load or update  
your system’s software. (Note that **.** denotes the level of the system software loaded on PC Card P/N 80051.)  
PC Card P/N 80051 is a system software PC Card only.  
You cannot use it to back up and restore site data.  
Backing Up Site Data  
To use PC Card P/N 85880 to back up site data:  
Mode Switch  
1. Insert PC Card P/N 85880 into the CPU (see the figure  
at right).  
PC Card Active  
LED  
2. Be sure the CPU mode switch is set to RUN.  
3. Enter the programming mode.  
ICM + #*#* + 372000 + HOLD  
4. Dial 9906 + HOLD.  
You see: START?  
To quit program 9906 instead of going to the next step,  
dial N + HOLD.  
T
E
LA  
T
Y
B
INSER  
EGA  
E
IN  
H
S
M
L
F
5. Dial Y + HOLD.  
R
A
.cng.nec.com  
www  
Inc.  
You see: 9906: DATABASE NAME  
NEC America,  
6. Enter a name for the database you want to save (up to  
10 characters long).  
Refer to Keys for Entering Names at right if you need help  
when entering names.  
Skip this step if you want to save data in an address  
that already has a name assigned.  
Keys for Entering Names  
Then one of these keys to enter the character in the white cell:  
Press this  
key:  
7. When you are done entering the name, press HOLD.  
You see the name and date of the first database stored.  
If no databases are stored, you see: 9906: DB00  
(empty)  
1
2
3
4
#
1
1
1
1
1
&
- (dash)  
/ (backslash)  
(apostrophe)  
2
3
4
5
6
7
8
9
0
*
A
B
E
H
K
N
Q
U
X
:
C
F
I
2
3
4
5
6
7
8
9
0
*
D
8. The system assigns the name you entered in step 7 to  
the address you select below:  
Press VOL L or VOL L to scroll through the 16 data  
base addresses (DB 00 through DB 15).  
OR  
G
J
L
O
R
V
Y
M
P
T
S
Z
Skip this step to select the currently displayed data  
base.  
W
SPACE  
9. Press HOLD.  
Normally, you see 9906: SAVING . . . . . . . . .  
The PC Card Active LED is on during backup.  
If the address you choose already has data stored in it,  
you see: REPLACE DB nn Y/N.  
#
To enter characters in lower case (e.g., e instead of E), press MW before pressing the key in the  
rst shaded column. Use LND to backspace over (erase) any characters you want to correct.  
1
In software versions prior to 02.00.00, the codes for 1 + 2, 1 + 3, and 1 + 4 were not available.  
- Press N + HOLD to back up to step 5.  
- Press Y + HOLD to proceed.  
You automatically exit programming when the backup  
completes.  
Continued  
 

Lasko Fan 2137 User Manual
LG Electronics Projector Accessories 42SH7DB User Manual
LG Electronics Refrigerator LMXS30776D User Manual
Life Fitness Home Gym 95LEZ 0XXX 01 User Manual
LOREX Technology Digital Camera SG21CD7444 User Manual
Lux Products Thermostat PSP300 Series User Manual
Makita Drill 8444DWDE User Manual
Makita Trimmer 3708FCMJ User Manual
Maxtor Computer Drive STM310005CAA00G RK User Manual
Memorex MP3 Player MMP3774 User Manual